SRX650: After the RG0 switchover, the Node 0 traffic is abnormal.

$
0
0

Dear anyone,

 

The master control plane switches from Node1 to Node0. The master data plane is on Node0. Node0 traffic abnormality occurred.

 

SRX650 [12.3X48-D30.7];

 

Node0 found some log,

 

Dec 30 00:26:48 2016   : %PFE-3:  PFEMAN: mastership change is found. from secondary to primary. 
Dec 30 00:26:48 2016   : %PFE-3:  PFEMAN: Master socket closed 
Dec 30 00:26:48 2016   : %PFE-3:  PFEMAN disconnected; PFEMAN socket closed abruptly 
Dec 30 00:26:48 2016   : %PFE-3:  CMLC: Master closed connection (errno=0) 
Dec 30 00:26:48 2016   : %PFE-0:  CMLC: Going disconnected; Routing engine chassis socket closed abruptly    
Dec 30 00:26:48 2016   : %PFE-5:  Routing engine PFEMAN reconnection succeeded after 1 tries 
Dec 30 00:26:48 2016   : %PFE-5:  PFEMAN master RE reconnection made 
Dec 30 00:26:48 2016   : %PFE-3:  CMLC: Retrying master connection, attempt 1 to 0x1300001 
Dec 30 00:26:48 2016   : %PFE-3:  CMLC: Lost contact with master routing engine 
Dec 30 00:26:48 2016   : %PFE-3:  CMLC: Forwarding will cease in 4 minutes, 59 seconds  -----> What does this mean, abort forwarding?   
Dec 30 00:26:48 2016   : %PFE-3:  usp_trace_ipc_disconnect:Trace client disconnected. Attempting to reconnect 
Dec 30 00:26:48 2016   : %PFE-3:  usp_trace_ipc_reconnect:USP trace client cannot reconnect to server 
Dec 30 00:26:48 2016   : %PFE-3:  PFEMAN: unknown timer type 20 
Dec 30 00:27:02 2016   /kernel: %KERN-3: if_pfe_peek_peer_info: Socket 0xc4be8000 error 64
Dec 30 00:27:02 2016   /kernel: %KERN-3: pfe_listener_common_task: Error. Socket 0xc4be8000 closed.
Dec 30 00:27:07 2016   : %PFE-3:  CMLC: Retrying master connection, attempt 50 to 0x1300001 
Dec 30 00:27:13 2016   flowd_octeon_hm: %USER-3: flowd_srx_i2c_read: Reading i2c data, dev 0x77 group 0x3 (ret = 1) [Resource temporarily unavailable] retry attempt 2  
Dec 30 00:27:19 2016   flowd_octeon_hm: %USER-3: flowd_srx_i2c_write: failed writing device at offset 0 (ret = -1) [Resource temporarily unavailable]
Dec 30 00:27:16 2016   eventd: %SYSLOG-3: sendto: No buffer space available

……………………6
Dec 30 00:27:46 2016   snmpd[92257]: %DAEMON-3-SNMPD_SEND_FAILURE: trap_io_send_trap_now: send to (10.0.19.37) failure: No buffer space available
Dec 30 00:27:46 2016   snmpd[92257]: %DAEMON-3-SNMPD_SEND_FAILURE: trap_io_send_trap_now: send to (10.0.19.58) failure: No buffer space available
Dec 30 00:27:26 2016   dcd[92259]: %DAEMON-3:  get_fpc_i2cid_from_ifd: Cannot determine FPC i2cidDec 30 00:27:38 2016   /kernel: %KERN-1-STP: STP IPC op 1 (ForwardingState) failed, err 1 (Unknown)  ----->What does it mean ?
Dec 30 00:27:38 2016   /kernel: %KERN-1-STP: STP IPC op 1 (ForwardingState) failed, err 1 (Unknown)
Dec 30 00:27:38 2016   : %PFE-3:  CMLC: Retrying master connection, attempt 100 to 0x1300001 

Dec 30 00:27:43 2016   : %PFE-3:  CMLC: Clearing disconnected; RE connection re-established

Dec 30 00:43:58 2016   : %PFE-3:  usp_ipc_server_send: failed to send message via ipc pipe 
Dec 30 00:43:59 2016   : %PFE-3:  usp_ipc_server_msg_handler: failed to send eom message
Dec 30 00:27:20 2016   /kernel: %KERN-4: ge-0/0/0:tag-protocol-id not configurable on this interface
Dec 30 00:27:20 2016   /kernel: %KERN-4: ge-0/0/1:tag-protocol-id not configurable on this interface
…………
Dec 30 00:27:21 2016   /kernel: %KERN-5-KERN_LACP_INTF_STATE_CHANGE: lacp_update_state_userspace: cifd ge-1/0/4 - DETACHED state - will not carry traffic
Dec 30 00:27:21 2016   : %PFE-3:  JBCM(1/0):jbcm_sfp_eeprom_read: write to i2c switch failed 
Dec 30 00:27:21 2016   /kernel: %KERN-4: ge-1/0/6:tag-protocol-id not configurable on this interface
Dec 30 00:27:21 2016   : %PFE-3:  JBCM(1/0):jbcm_sfp_eeprom_read: write to i2c switch failed 
Dec 30 00:27:21 2016   : %PFE-3:  JBCM(1/0):jbcm_sfp_eeprom_read: write to i2c switch failed 
Dec 30 00:27:21 2016   : %PFE-3:  CMLC: Lost contact with master routing engine 
Dec 30 00:27:21 2016   : %PFE-3:  CMLC: Forwarding will cease in 4 minutes, 26 seconds 
Dec 30 00:27:22 2016   /kernel: %KERN-1-RT_PFE: NH IPC op 11 (DELETE NEXTHOP) failed, err 7 (Doesn't Exist) peer_class 0, peer_index 0 peer_type 10
Dec 30 00:27:22 2016   /kernel: %KERN-1-RT_PFE: NH IPC op 11 (DELETE NEXTHOP) failed, err 7 (Doesn't Exist) peer_class 0, peer_index 0 peer_type 10

What is happening ? Where is the problem ? Software or hardware ?

 

Who encountered a similar problem?

 