Adding SPC cards to an SRX5800

$
0
0

So we have an SRX5800 cluster, with both devices having two SRX5K-SPC-2-10-40 SPC cards installed in FPC slots 10 & 11 (the highest slots).

 

If we want to add a new SRX5K-SPC-2-10-40, what is the process? Considering that if I'm reading the following page correctly, we cannot simply just add a new card into slot 9 since it's a lower slot:

 

https://www.juniper.net/documentation/en_US/release-independent/junos/topics/task/installation/spc-srx5800-installing.html

 

  • If you are only adding first-generation SRX5K-SPC-2-10-40 SPCs to the chassis, you must install them so that the new SPCs are not the SPCs with the lowest-numbered slots in the chassis. For example, if the chassis already has two SPCs with one SPC each in slots 2 and 3, you cannot install additional SPCs in slots 0 or 1 using this procedure.