Re: Panel LED Frontal blinking RED - Online MX
Robert, The mentioned PR states that chassisd coredumps will be seen so I suspect it could be our case? Since when did you notice the problem with the LED? Lets try rebooting and see if it gets fixed....
View ArticleRe: Dynamic VPN (SRX300)
Currently, dynamic VPN connections to the SRX are only support if you are using either Pulse or NCP clients. Pulse:...
View ArticleRe: Dynamic VPN Configuration (SRX 340)
Thanks for the responses everyone. I will be working through these and providing my results. It will likely be Monday before I have anything, but once I do I will be sure to post them. Thanks again for...
View ArticleRe: Panel LED Frontal blinking RED - Online MX
Right. We noticed the LED a few days ago and have been doing tshoot to understand why.We are scheduling the box reset to start next week. Coming soon with more news. Thank you so much for your support.
View ArticleRe: Panel LED Frontal blinking RED - Online MX
Hi RobertA reboot should most likely fix the issue. We can then upgrade to a build with the fix of both PRs to prevent that in the future.
View ArticleRe: Dynamic VPN (SRX300)
Thanks for the quick reply! I'm trying to establish a policy-based VPN where one side has a dynamic IP. All of the documentation for site-to-site VPNs seem to require static IPs. For example...
View ArticleRe: Dynamic VPN (SRX300)
ajwilder, If the VPN peer has a dynamic IP address you will need to slighty modify the configuration, specifically on the following aspects: 1. mode aggressive has to be used: set security policy...
View ArticleRe: a factory default security policy
Hello, yes, i have a portforwarding D-NAT towards srx inside network.
View ArticleRe: Dynamic VPN (SRX300)
Thanks again! Unfortunately, I had those settings in place already. Here is what I've got: admin@Firewall> show version Hostname: Firewall Model: srx300 Junos: 19.2R1.8 JUNOS Software Release...
View ArticleJunos upgrade fails on SRX340 cluster (from 15.1X49-D170.4 to 17.3R1.10)
Hi guys, I´m trying to upgrade the Junos on a SRX340 chassis cluster, currently running 15.1X49-D170.4.Attending to the upgrade path shown here...
View ArticleRe: process extensive
Hello RES refers to actual RAM usage by the process, while SIZE also includes files mapped by the process. So if large size files are mapped by the process SIZE would be much higher than RES. I do not...
View ArticleRe: Junos upgrade fails on SRX340 cluster (from 15.1X49-D170.4 to 17.3R1.10)
Hello, This should work. I checked some reported issues and did not find anything similar. We had some kernel panic issues earlier, but honestly the code you are running should not be impacted....
View ArticleRe: Junos upgrade fails on SRX340 cluster (from 15.1X49-D170.4 to 17.3R1.10)
Hi Trasgu, If you ever stuck in db> prompt, please issue db> cont or db> reset. In case if the above command, doesn't help we can proceed with the reboot of the device. If you were unable to...
View ArticleRe: Junos upgrade fails on SRX340 cluster (from 15.1X49-D170.4 to 17.3R1.10)
The only time you should use no validate is when you have a kb article that says to as part of a larger procedure. The key here will likely be to determine why validation of the config failed. Use just...
View ArticleFail - IP-MONITORING DUAL ISP
Guys could someone help me? I have an SRX300 with two ISPs. ISP 1 - VPN ISP 2 - Internet However when ISP2 fails ISP1 does not surf the internet. ip-monitoring { policy INTERNET-ISP2 { match {...
View ArticleRe: SRX5600 dual manment modules
The RE that is working on each node is the one installed on slot 0. If the RE that failed in your scenario was the one in slot 0 then it is expected that your cluster was broken. If the backup RE (the...
View ArticleRe: SRX5600 dual manment modules
be infomred that i have 2 RE each node. and 1 control link not 2 control link . Hardware inventory:Item Version Part number Serial number DescriptionChassis JN124E9FDAGB SRX5600Midplane REV 01...
View ArticleRe: SRX5600 dual manment modules
Hello Amr, The RE sits as a daughter card on the SCB (Switch control board). RE0 in CB0 and RE1 in CB1. In the output you have shared I see neither CB1 nor RE1. Am I missing something here? This could...
View ArticleAbout appliaction-name?
What is application-name in application statement?It's a name of application (then where can i find this name) or i can set whatever i want?sorry it's a naive question thank you!
View ArticleRe: About appliaction-name?
Hello, It is just a name. Any identifier you may want to give. In the below example the application name is TCP-5050. set applications application TCP-5050 protocol tcp destination-port 5050 Regards,...
View Article