Re: error: Could not connect to node1 : No route to host - after power failure

$
0
0

Hello ,

 

First of all , you are missing the secondary FAB port from secondary Node which should be " ge-5/0/7 "  .

 

Secondly the secondary FAB link  "ge-0/0/7" and ge-5/0/7" connecting switch port on CISCO should be in different VLAN  as a best practice ( With Jumo Frames enabled ) . Thats why we are getting the errors as the FAB probs are getting confused between the  Primary and secondary FAB link .

And also this should be in same VLAN as of other revenue ports .

 

Now regarding your Failback issue , it seems to be something that need to be checked why it takes almost  30 mins to failback and  It may be out of scop of the device ( Maybe the switch might also have causing this ) but they need to identify the issue so that we can proceed .   Did the support say if this is a supported setup or not ?

 