srx5400 HA cluster and dual SPC

$
0
0

Hi,

 

I've got two srx5400, each with two SPC cards in a HA cluster.

I am aware srx5400 can have only one RE so only control port 0 (em0) can be used.

All of dual control link configuration references are for srx5600/5800 when two REs are present - when both HA control  port 1 and 0 on the SPC are used.

 

But what about dual control port 0, from each of the two SPCs?

 

So currently i've got:

control-ports {
fpc 1 port 0;
fpc 4 port 0;
}

 

Can i have this?

control-ports {

fpc 0 port 0;
fpc 1 port 0;

fpc 3 port 0;
fpc 4 port 0;
}

 

Also to note, the FPC0 SPC which isn't connected to its counterpart on the other node doesn't have the HA led ON.

 

Any reference to documentation explaining this is welcome.

 