Re: error: Could not connect to node1 : No route to host - after power failure

Hi Nikolay,I think you experienced expected behaviour.The Layer2 loop issue I had appeared on the ports connected to the powered up device when the other device went offline. The SRX device was...

View Article


Re: Transparent mode: Redundant connection between Juniper SRX340 and Cisco...

Hi rsuraj, I have to deploy static Etherchannel on the Cisco Catalyst 3750-X. The switch is within a productive datacenter network.Since I have never configured static Etherchannel I am afraid of...

View Article


Re: SRX110 connectivity

Sorry, but you are not providing enough information to help.   Which ping test are you using and exactly what result do you get?If you are using the ping www.microsoft.com, does the name show a...

View Article

Re: Add DMZ on single IP

This configuration is simply not valid:vlan { unit 0 { family inet { address 192.168.5.1/24; } } unit 1 { family inet { address 192.168.5.80/24; } } } }You are assigning overlapping ip addresses to...

View Article

Re: Add DMZ on single IP

Yes i'm "simply" trying to create a connection to ps4 (ip 192.168.5.80/32) with all ports and services opened like dmz.Also my adsl it has dynamic ip.Thanks

View Article


Image may be NSFW.
Clik here to view.

SRX100 is dead

I have an SRX100 that does not boot up. When I plug it in with the console attached nothing is shown on console. All the LEDs light up and stay on. I have tried changing the little CR2032 battery...

View Article

Re: SRX100 VPN problem

You need to configure proxy-arp for the client addresses. This will allow the SRX to respond to arp requests made by other hosts for your dynamic VPN clients. set security nat proxy-arp interface...

View Article

Re: Policy based vpn up but no traffic

Maybe you should share the configuration.

View Article


Re: Add DMZ on single IP

I had a look over at Playstation support and understand a little better what issues there are.  The short version is to have real support for what Playstation and Xbox want you need a firewall that...

View Article


Re: SRX100 and BT infinity problem

Hi, thanks for replying.So I tested the incoming-mail destination NAT rule by redirecting my emails to xxx.142.86.45  but it didn't work. When running 'show security nat destination rule all' I can see...

View Article

Re: SRX100 and BT infinity problem

Although you are sending events to the control plane from the data plane with the 'security log mode event', you are only logging critical alarms to the messages log file which may explain why you...

View Article

Re: SRX100 and BT infinity problem

Thanks, I can now see the traffic via Cli (still unable to see anything in policy log in web browser though, but this isn't my biggest concern right now). Yes, DG is exactly the same accross the...

View Article

Re: SRX100 and BT infinity problem

Are you able to configure another network within the trust zone and attempt to use any of the services from that network? It would eliminate the specific security policies and the NAT. That might help...

View Article


Re: VPN failed with SRX300 and SRX100

Dears,  Sorry for late reply. I found out my release version is old and don't support VPN policy base. Now, I 'm upgrade to 15.1X49-D50. But tunnel is still in down. Finally, I change to route base and...

View Article

Re: Traffic logging on srx branch series

AFAIK, This only works when you enable web-filtering , and this request a license .

View Article


Re: SRX100 is dead

Hello , Have yu tried to use a different consol cable ?  Since you said you are getting power light UP , it may be the consol issue . If you still does not get anyout from a different consol cable ,...

View Article

Re: Policy based vpn up but no traffic

Hello ,As per the output is shared  , the traffic from SRx end is going into the tunnel , thats why it shows the encrypt packet getting incremented .  Also the session details shows that same . But we...

View Article


Re: SRX100 is dead

Thanks but definately not the console cable. All the LEDs light up including the ones on the ports but they remain up which is not normal. There is no service contract on the unit.

View Article

Re: SRX100 is dead

the dfault config come with 192.168.1.1/24 IP configured on interfaces 1 to 7, try connecting any machine with 192.168.1.2/24 and GW as 192.168.1.1 and ping. Just to see if anything is active. if no...

View Article

Re: SRX100 is dead

Are you using the "standard" serial connection settings ? 9600,N,8,1?Did you try to reset the SRX to factory defaults?  --If this post solves your problem, please mark this post as "Accepted...